Product Detail
6AV6644-0AA01-2AX0,SIMATIC Panel
Artikelnummer6AV6644-0AA01-2AX0 SIMATIC MP 377 12" TOUCH MULTIPANEL, WINDOWS CE 5.0 12" COLOR-TFT-DISPLAY 12 MB USER MEMORY CONFIGURABLE FROM WINCC FLEXIBLE 2007 ******************************* THIS PRODUCT IS NO LONGER AVAILABLE FROM OCT. 1ST, 2014. INFORMATION ABOUT SUCCESSOR SEE SIMATIC UPDATE ID: 62977695 FOR FURTHER QUESTIONS PLEASE APPROACH YOUR SIEMENS CONTACT PERSON.General informationCustomer-specific configurationNoDisplayDesign of displayTFTScreen diagonal12.1 inSize12.1" (246 mm x 184.5 mm)Display typeTFT, 65536 colorsNumber of grayscales0Color typeColorsResolution (pixels)● Horizontal image resolution800● Vertical image resolution600● Resolution (WxH in pixel)800 x 600Backlighting● MTBF backlighting (at 25 °C)50 000 hControl elementsControl elementsTouch screenOperating optionsTouchConnection for mouse/keyboard/barcode readerUSB / USB / USBKeyboard● Keys with LEDNo● Numeric/alphabetical inputYes / Yes— hexadecimal keyboardYesTouch operation● Design as touch screenYesSupply voltageType of supply voltageDCInput currentRated current1.5 APowerPower36 WMemoryUsable memory for user data12 288 kbyteTime of dayClock● TypeHardware clock, battery backup, synchronizable● Hardware clock (real-time clock)Yes● Battery-backedYes● SynchronizableYesInterfacesInterfaces1 x RS422, 1 x RS485, 2 x Ethernet (RJ45)Number of RS 485 interfaces1USB port2 x USBCF card slot1 x CF card slotMulti Media Card slot1x Multimedia Card slot, up to 128 MBIndustrial Ethernet● Industrial Ethernet interface2 x Ethernet (RJ45)ProtocolsSupports protocol for PROFIsafeNoPROFIBUSYesMPIYesProtocols (Ethernet)● TCP/IPYesProtocols (terminal link)● Sm@rtServiceYesFurther protocols● other bus systemsYesEMCEmission of radio interference acc. to EN 55 011● Limit class A, for use in industrial areasYesDegree and class of protectionFrontIP65, NEMA 4, NEMA 12 (when installed)IP (at the front)IP65IP (rear)IP20Standards, approvals, certificatesCertificationsCE, FM Class I Div. 2, cULus, EX-Zone 22, C-TICK, NEMA 4, NEMA 12cULusYesEMCThe product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information please refer to the user documentation.Suitable for safety functionsNoUse in hazardous areas● EX zone 22Yes● FM Class I Division 2YesAmbient conditionsmaximum permissible angle of inclination without external ventilation+/- 35 °Storage/transport temperature● Transport, storage-20 °C to +60 °CRelative humidity● Operation, max.90 %Operating systemsOperating systemWindows CEConfigurationMessage indicatorYesWith alarm logging system (incl. buffer and acknowledgment)YesProcess value display (output)YesProcess value default (input) possibleYesRecipe administrationYesConfiguration software● STEP 7 Basic (TIA Portal)No● STEP 7 Professional (TIA Portal)No● WinCC flexible CompactNo● WinCC flexible StandardYes● WinCC flexible AdvancedYes● WinCC Basic (TIA Portal)No● WinCC Comfort (TIA Portal)Yes● WinCC Advanced (TIA Portal)Yes● WinCC Professional (TIA Portal)Yes● Configuration toolWinCC flexible Standard Version 2007 or higher (to be ordered separately)● 2nd configuration kitWinCC flexible Standard— VersionVersion 2007— Configuration toolWinCC flexible— TypeStandardLanguagesOnline languages● Number of online/runtime languages16Languages● Languages per project32Functionality under WinCC (TIA Portal)LibrariesYesTask plannerYesHelp systemYes● Number of characters per info text70Message system● Number of alarm classes32● Number of messages4 000● Bit messagesYes● Analog messagesYes● Number of bit messages4 000● Number of analog messages200● Telegram message procedure Alarm SYes● System messages HMIYes● System messages PLCYes● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)Yes● Message length (in characters)80● Lines1● Number of process values per message8● Message indicatorYes● First/last valueYesRecipe administration● Number of recipes500● Data records per recipe1 000● Entries per data record1 000● Recipe memory128 KB integrated Flash, expandableVariables● Number of variables per device4 096; Configuration with WinCC flexible 2008 and higher● Number of variables per screen400● Number of variables2 000● Initial values2 048● Limit valuesYes● MultiplexingYes● StructsYes● Type Date & Time2 048Images● Number of configurable images500● Permanent window/defaultYes● Start screen configurableYes● Image selection by PLCYes● Image number in the PLCYesImage objects● Text objects30000 text elements● Fields per image400● Date/time fields400● ReturnYes● Graphics objectBit maps, icons, vector graphics— Icons2 000Complex image objects● Status/controlWith SIMATIC S7● dynamic objectsDiagrams, bar graphs, sliders, analog display, invisible buttons— Number of objects per project2 000— Number per image20● MethodsTrend / profile● Limit value linesYes● Number of bars per chart20● Limit value linesYes● alphanumeric fields300● alphanumeric fields per image400● numerical fields2 048● numerical fields per image400● Password errors2 048● Number of slides per image20● Number of analog indicators per image20● Number of visible switches per project400● visible switches per image400● hidden switches per image400● Number of status switches per project400● Button status switches per image400● Number of selector switches per project400● Selector switches per image400● Number of signal lamps per project400● Signal lamps per image400Attributes for dynamic objects● Color changeYes● X/Y movementYes● HideYesLists● Number of text lists per project500● Number of text lists per image400● Number of entries per text list256● Number of graphics lists per project500● Number of graphic lists per image400● Number of entries per graphics list256Archiving● Number of archives per device50● Number of measuring points per project50● Number of entries per archive50 000● Message archiveYes● Process value archiveYes● Archiving methodsSequence archive, circular log, alarm log, process value archive— Sequential archiveYes— Short-term archiveYes● Memory locationCF card, SD/MMC card, Ethernet, USB memory stick— CF cardYes— EthernetYes● Data storage formatCSV file, readable, e.g. with MS Excel, MS Access— CSVYes● external evaluationReadable, e.g. with MS Excel, MS Access, etc.● Size of archivedepending on free memory on ext. card/stick or on free hard disk space via network drive● Online evaluationvia trends— via trendsYesFilters● cyclicYes● ToleranceYes● ChangeYesSecurity● Number of user groups50● Number of user rights32● Password export/importYesData carrier support● CF cardYes● Hard diskYesLogging through printer● Recording/PrintingAlarms, report (shift report), color print, hardcopyTransfer (upload/download)● Transfer of configurationMPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognitionProcess coupling● Connection to controllerS5, S7-200, S7-300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces"● S7-1200Yes● S7-1500Yes● S7-200Yes— PPI (point-to-point)Yes— PPI networkYes— MPIYes— PROFIBUS DPYes● S7-300/400Yes— MPIYes— PROFIBUS DPYes— PROFINETYes● S5Yes— PROFIBUS DPYes● TI 505Yes● Allen Bradley (DF1)Yes● Allen Bradley (DF485)Yes● Mitsubishi (FX)Yes● Mitsubishi (MP4)Yes● Telemecanique (Uni-Telway)Yes● OMRON (LINK/Multilink)Yes● Modicon (Modbus)Yes● GE-Fanuc (SNP)YesFunctions● TAB sequenceYes● Calculating functionsYes● AnimateYesService tools/configuration aids● Clean screenYes● Touch calibrationYes● Backup/restoreYes● SimulationYes● Device switchoverYes● Delta transferYesExpandability/openness● Open Platform ProgramYesI/O / OptionsI/O devicesPrinter, card reader, barcode reader● MultiMediaCardYes● SD cardYes● USB memoryYesAdditional software components loadableYesDimensionsWidth of the housing front335 mmHeight of housing front275 mmMounting cutout/device depth (W x H x T)310 mm x 248 mm / 72 mm device depthWeightsWeight (without packaging)3.8 kglast modified:25.09.2015 We Resell Full New Siemens HMI, Price is 10%-30% cheaper than other countries.SeriesModelDescriptionSIMATIC Basic Panels (1st Generation)6AV6647-0AA11-3AX0KTP400 BASIC MONO PN,, KEY AND TOUCH, 4"6AV6647-0AK11-3AX0KTP400 BASIC COLOR PN, KEY AND TOUCH, 4"6AV6647-0AB11-3AX0KTP600 BASIC MONO PN, KEY AND TOUCH, 6"6AV6647-0AC11-3AX0KTP600 BASIC MONO PN, KEY AND TOUCH, 6"6AV6647-0AD11-3AX0KTP600 BASIC MONO PN, KEY AND TOUCH, 6"6AV6647-0AE11-3AX0KTP1000 BASIC COLOR DP, KEY AND TOUCH, 10"6AV6647-0AF11-3AX0KTP1000 BASIC COLOR DP, KEY AND TOUCH, 10"6AV6647-0AH11-3AX0KP300 BASIC MONO PN, KEY OPERATION, 3"6AV6647-0AJ11-3AX0KP400 BASIC COLOR PN, KEY OPERATION, 4"6AV6647-0AG11-3AX0TP1500 BASIC COLOR PN, TOUCH OPERATION, 15"SIMATIC HMI Basic Panels(2nd Generation)6AV2123-2DB03-0AX0KTP400 BASIC, KEY AND TOUCH OPERATION, 4"6AV2123-2GA03-0AX0KTP700 BASIC DP, KEY AND TOUCH OPERATION, 7"6AV2123-2GB03-0AX0KTP700 BASIC, KEY AND TOUCH OPERATION, 7"6AV2123-2JB03-0AX0KTP900 BASIC, KEY AND TOUCH OPERATION, 9"6AV2123-2MA03-0AX0KTP1200 BASIC DP, KEY AND TOUCH OPERATION, 12"6AV2123-2MB03-0AX0KTP1200 BASIC, KEY AND TOUCH OPERATION, 12"Siemens Comfort Panel6AV2124-2DC01-0AX0KTP400 COMFORT,TOUCH AND KEY OPERATION,4"6AV2124-1DC01-0AX0KP400 COMFORT,KEY OPERATION,4"6AV2124-0GC01-0AX0TP700 COMFORT,TOUCH OPERATION,7"6AV2124-1GC01-0AX0KP700 COMFORT,KEY OPERATION,7"6AV2124-0JC01-0AX0TP900 COMFORT,TOUCH OPERATION,9"6AV2124-1JC01-0AX0KP900 COMFORT,KEY OPERATION,9"6AV2124-0MC01-0AX0TP1200 COMFORT,TOUCH OPERATION,12"6AV2124-1MC01-0AX0KP1200 COMFORT,KEY OPERATION,12"6AV2124-0QC02-0AX0TP1500 COMFORT,TOUCH OPERATION,15"6AV2124-1QC02-0AX0KP1500 COMFORT,KEY OPERATION,15"6AV2124-0UC02-0AX0TP1900 COMFORT,TOUCH OPERATION,19''6AV2124-0XC02-0AX0TP2200 COMFORT,TOUCH OPERATION,22"ShippingDHL, UPS, Fedex, TNT, EMS, PostPaymentT/T, Western Union, Moneygram, PaypalMinimum Order Quantity1 pcsTechnical SupportfreeProgramming Softwarefree